Page Title: Table 2-3. Troubleshooting
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 11-6130-429-40
Table 2-2. Converter Bench Test-Continued
Indication
Procedure
Step
19
a. Increase output current to 75 ADC.
b. Decrease input voltage to 21 VDC.
c. Measure output voltage at front panel (+5V P1 and +5V RTN).
Voltage shall be +5V and 0.1V.
20
Using the oscilloscope, measure the output ripple at P1 connector.
Ripple voltage shall be less than 150 MV.
Table 2-3. Troubleshooting
MALFUNCTION
TEST OR INSPECTION
CORRECTION ACTION
1. BLOWER NOT OPERATING, FAULT LAMP NOT LIT, ON/OFF SWITCH OFF.
Using multimeter, check continuity of Input EMI Filter and related components.
Repair wiring/replace defective components.
2. BLOWER NOT OPERATING, FAULT LAMP LIGHTED, ON/OFF SWITCH OFF.
Using multimeter, check continuity from P1-A1/P2-A1 to + terminal of blower B1 and from P1-A2/P2-A2 to - terminal of
B1.
Repair wiring/replace defective blower B1.
3. BLOWER OPERATES, FAULT LAMP NOT LIGHTED, ON/OFF SWITCH OFF.
Step 1. Using multimeter check continuity of bulb in FAULT lamp holder XDS1.
Replace defective bulb.
Step 2. Using multimeter, check continuity of wiring from L2B pin 4 to pin 1 of FAULT lamp DS1 and L2A pin 2 to pin 1 of
DS1.
Repair defective wiring/replace defective S1, R1 or lampholder XDS1.
4. BLOWER OPERATES, FAULT LAMP MAY OR MAY NOT BE LIGHTED, ON/OFF SWITCH ON, NO OUTPUT.
Step 1. Input EMI Filter and Related Components (P/O Main Frame) Check. Using multimeter, check continuity from P1-A1
and P2-A1 to J2-2 and from P1-A2 and P2-A2 to J2-1, with ON/OFF switch (S1) ON.
Repair wiring/replace S1. Replace defective component.
NOTE
The following tests require preliminary setup procedures.
PRELIMINARY SETUP PROCEDURES
1. Set converter ON/OFF switch to OFF.
2. Setup equipment as shown in figure 2-3.
3. Position cooling fan to circulate air around heatsink and rear panel.
4. Set test equipment controls as follows.