TM 11-6130-429-12
4-4. SERVICE UPON RECEIPT CHECKS AND INSPECTIONS - Continued
REMARKS
ACTION
ITEM
LOCATION
PERFORMANCE CHECK
Set to 10 Vdc scale.
1. Multi-
Function
meter
switch
OFF (applies to initial installation only).
2. Front
ON/OFF
panel
switch
Insert multimeter BLACK lead.
+5V RTN
+5V P1
Insert multimeter RED lead.
ON.
ON/OFF
switch
If voltage is between +4.5
Observe indication; should be
Range
3. Multi-
+5 volts 0.1 Vdc.
and +5.5 volts, no adjust-
meter
scale
ment is necessary.
If voltage is less than +4.5,
or more than +5.5 volts dc
perform ADJUSTMENT
procedures.
4. Front
OFF.
ON/OFF
panel
switch
+5V P1
Remove multimeter RED lead.
+ 5V P2
Insert multimeter RED lead.
ON.
ON/OFF
switch
Same remark as for step
5. Multi-
Range
Observe indication; should be
3 above.
meter
+5 volts 0.1 Vdc.
scale
OFF.
6. Front
ON/OFF
panel
switch
Remove multimeter leads from equipment.
Converter is now ready for operator's use.
CAUTION
DO NOT LET MULTIMETER LEADS HANG
TOO CLOSE TO BLOWER IF CONVERTER
IS OPERATING.