TM 11-6125-259-30
weight, modularized inverter and contains solid
Overload and Short
15 minutes, recovers within 2
Circuit Protected:
state circuits throughout. The inverter is self-cooled
seconds after removal of
overload or short circuit
by natural convection, conduction, radiation and an
To 50,000 feet, rated power
Operating Altitude:
internal  fan.
To 65,000, half rated power
minimum
1-8. Tabulated Data
Operating
-56 to +85C
Temperatures:
Input Voltage:
18 to 29 vdc (28 vdc at 17.4
Dimensions (max):
11-1/2 inches long
amps, nominal)
5-1/2 inches wide
115 vac rms, nominal, at 2.17
Output voltage:
8 inches high
amps
Mounting:
Four 0.397-inch diameter
112.5 to 117.5 vac rms (at 26
holes, 4 X 5-inch centers
to 29 vdc input), 3
Weight:
23 lbs maximum
100.0 to 117.5 vac rms (at 18
Connectors:
J1, type MS3102R22-6P
to 26 vdc input,) 3
J2, type MS3102R22-5S
250 va at 0.75 amps per phase
Output Power:
Test Points:
Measures output voltage,
Output Frequency:
393 to 407 Hz (at 18 to 29 vdc
located adjacent to J2
input)
Input Connector, J1, pins:
A (-)
ABC
Phase Rotation:
C (+)
Output Full Load:
250 va phase, 750 va total, 0.75
B Not Used
PF minimum lagging
Minimum Efficiency:
65% at full load (unit PF)
}
Output connector, J2, pins:
AA
and 28 vdc input, room am-
BB
3
bient
CC
Output
Output Distortion
5% maximum phase (at 18 to 29
vdc input)
}
DB
3 . 2 5 volts peak-to-peak
Output
EC
maximum
Return
PA
EL7PIOO2
Figure 1-2. Output Connection Configurations.