Click here to make tpub.com your Home Page

Page Title: Table 4-2. ORGANIZATIONAL MAINTENANCE TROUBLESHOOTING
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 11-6130-429-12
Table 4-2. ORGANIZATIONAL MAINTENANCE TROUBLESHOOTING
REMARKS
STEP
INSTRUCTION
INDICATION
YES
NO
x
Blower operates
Continue trouble-
shooting.
x
Observe FAULT lamp.
x
Blower not operating;
FAULT lamp lighted
replace converter.
1
POWER OFF
x
Blower not operating;
check rack power
source; Blower
operating replace
indicator bulb.
x
Go to 3.
FAULT lamp goes out
x
Continue trouble-
shooting,
2
POWER ON
FAULT lamp lighted;
x
Demand downstream
replace converter.
x
Go to 3.
x
Return to service.
+5V 1.5 volts
Using multimeter,
check output at
+5V P1 and
x
If FAULT lamp is
+5V P2.
3
lighted, voltage
cannot be adjusted. .
Adjustment pro-
cedures are listed
4-10

Privacy Statement - Press Release - Copyright Information. - Contact Us