TM-11-6130-429-12 Converter Direct Current CV=3734/T Manual
Next
Equipment Function
TM 11-6130-429-12
Section Il. EQUIPMENT DESCRIPTION
1-8. EQUIPMENT CHARACTERISTICS, CAPABILITIES, AND FEATURES
PURPOSE OF CONVERTER
Supplies regulated DC voltage to equipment used in AN/TTC-38 or AN/TTC-39 mobile
telephone switching system.
CAPABILITIES AND FEATURES
External shutdown capability, from equipment or control panel converter supplies.
Automatic shutdown in the event of overload or underload conditions.
Emergency voltage adjustment.
Test points for monitoring output circuits.
1-9. EQUIPMENT DATA
WEIGHT AND DIMENSIONS
Rack Mounted
11.350 Kg (25 Ibs., approximate)
Weight
44.45 cm (17.50 in.)
Length
12.4 cm (4.88 in.)
Width
17.78cm (7.0 in. )
Height
ENVIRONMENTAL CONDITIONS
Ambient temperature
7 0 F ( 5 7 C ) to + 125F(+52C)
98 per cent
Relative humidity
Altitude
Up to 25,000 feet (7,500 meters) above sea level
TECHNICAL
CHARACTERISTICS
+5 volts direct current
Output voltage
+75 amperes
Output current
Nominal power
315 watts
21-30 volts direct current
Operating power requirements
Regulation Peak-to-Peak
0 to 10% 3% of full load,
Ripple and noise
10% to full load 2%
1-3